P/R60 & P/R65 Page 1 OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES N116-19 REV. 14
P/R60 & P/R65 Page 10 3.9. Sanitary Probe P60S, P65S, R60S, R65S a) The P60S is designed with a stainless steel flange to mate with a Tri-C
P/R60 & P/R65 Page 11 4.2. Replacement of Salt Bridge for Series 4, 6, 7 & S Differential Probes a) If the system cannot be calibrated
P/R60 & P/R65 Page 12 5. TROUBLESHOOTING AND SERVICE 5.1. Checking 5-wire Differential Probes P60 and R60 The probe can be checked by a f
P/R60 & P/R65 Page 13 5.2. Checking Probes P65 and R65 (4-20 mA output) a) The operation of the 2-wire, 4-20 mA, probe can be checked by
P/R60 & P/R65 Page 14 5.3. Customer Service If a problem has not been resolved with the above procedures, a telephone consulta
P/R60 & P/R65 Page 15 6. DRAWINGS 6.1. N106-61 SERIES 4 DIFFERENTIAL pH/ORP PROBES
P/R60 & P/R65 Page 16 6.2. N106-183 SERIES 6 DIFFERENTIAL pH/ORP PROBES
P/R60 & P/R65 Page 17 6.3. N106-184 SERIES 7 DIFFERENTIAL pH/ORP PROBES SERIES 8 DIFFERENTIAL pH/ORP PROBE
P/R60 & P/R65 Page 18 6.4. N106-182 SERIES 8 DIFFERENTIAL pH/ORP PROBES
P/R60 & P/R65 Page 19 6.5. N106-62 SERIES S DIFFERENTIAL pH/ORP PROBES
P/R60 & P/R65 Page 2 TABLE OF CONTENTS 1. GENERAL INFORMATION 4 2. SPECIFICATIONS 5 3. INSTALLATION 6 3.1. General Instructions 6 3.
P/R60 & P/R65 Page 20 6.6. N105-73 INSTALLATION OF SERIES 6 DIFFERENTIAL PROBES
P/R60 & P/R65 Page 21 6.7. N106-79 INSTALLATION OF SERIES 7 DIFFERENTIAL PROBES
P/R60 & P/R65 Page 22 6.8. N105-72 INSTALLATION OF SERIES 8 DIFFERENTIAL PROBE
P/R60 & P/R65 Page 23 6.9. N106-60 INSTALLATION OF SALT BRIDGE IN A DIFFERENTIAL PROBE
P/R60 & P/R65 Page 3 5.3. Customer Service 14 5.4. Parts and Accessories 14 5.5. Probe Return 14 6. DRAWINGS 15 6.1. N106-61 SERIES
P/R60 & P/R65 Page 4 1. GENERAL INFORMATION This manual covers all AquaMetrix P60, P65, R60
P/R60 & P/R65 Page 5 2. SPECIFICATIONS MEASURING RANGES pH: 0 to 14.00 pH ORP: R60: +1999 mV R65: 0-1000 mV / +
P/R60 & P/R65 Page 6 3. INSTALLATION 3.1. General Instructions Specific instructions for each type
P/R60 & P/R65 Page 7 Figure 1 - Wiring a P/R 60 to a Shark controller 3.3. Connecting the P/R 60 to a Shark TX/P a) Always power down th
P/R60 & P/R65 Page 8 Figure 2 - Wiring a P/R 60 probe to a Shark TX/P transmitter 3.4. ORP 4-20 mA Probes, R65
P/R60 & P/R65 Page 9 to the process. A cable strain relief fitting should be used on the upper end of the pipe. In the kits a wire bracket
Comentarios a estos manuales